新闻资讯

News Center

News Center > Company News

current position: Home > News Center > Company News

hot key wordsKeywords

contact usContact Us

Wenzhou Mocheng Automatic Control Valve Co., Ltd

contacts:Wang Libin

Mobile phone:+86 137 3200 6688

Contact Fax:+86 0577-67273593

Contact Email:mocem612@yeah.net

Contact address:Anfeng Industrial Zone, Oubei Street, Yongjia County, Wenzhou City, Zhejiang Province


Pneumatic actuator type selection

2021-10-23 08:22:39
times

Pneumatic actuator type selection

Pneumatic actuator drive device can be connected with a variety of computer, alone or centralized control, can use two analog or switch signal control, support various modern control equipment, widely used in domestic petroleum, chemical, electric power, metallurgy, textile, food, medicine, environmental protection, urban construction and the research field of zhu, exported to Europe, America, Middle East and southeast Asia market, It is well received by users.

Pneumatic actuator beautiful appearance delicate, light weight, waterproof sealing structure. Install the piston, rack and the moving parts of the output shaft F4 guide ring for low friction, long life and avoidance of metal contact. Meet the installation connection size ISO5211, DIN3337 and VD1 / VDE3845 and NUMAR standards to ensure easy installation of GTD solenoid valves. Limit switch and other accessories.

Type selection of double-acting pneumatic actuator:

With double-acting ACTUATORS, the valve torque must be determined first. Under normal service conditions, the recommended safety factor is 15 to 20%. Increase the safety value according to the fluid medium used. The safety value of lubricating medium is increased by 20%; The safety value of water vapor or non-lubricating liquid medium is increased by 25%; The safety value of non-lubricated slurry medium is increased by 40%; The safety value of non-lubricated dry gas medium increased by 60%; The safety value of non-lubricated granular medium is increased by 80%. The safety value of particle powder medium transported by non-lubricating gas increased by 100%; Based on the torque values calculated above and using the air source pressure to find the torque table of the dual function actuator, the GTD model can be accurately obtained.

Single action pneumatic actuator type selection:

Using a single action actuator, find a single action torque table according to the torque value and the air source pressure calculated above. First check the spring return end, and then check the air source working pressure end. The air source pressure torque should be greater than the spring return torque to get the exact model. Note: In GTE's single pneumatic output torque table, the spring reset "end" torque is the torque of closing the valve, and the spring reset "start" to open the valve, the torque is the torque. The starting torque of the corresponding air source pressure is the torque of the valve closing state, and the ending torque of the air source pressure is the torque of the valve opening.


Recently Viewed:

Related products

news.related_news

Copyright © Wenzhou Mocheng Automatic Control Valve Co., Ltd All rights reserved record number:浙ICP备19000689号-1 Mainly engaged inPneumatic actuator,Pneumatic valve actuator,Manufacturer of pneumatic valve, Welcome to inquire!
Technical Support: Wenzhou Successkj Co., Ltd

As the new Advertising Law stipulates that absolute words are not allowed to appear on all pages, we support and follow the Advertising Law. In order not to affect consumers' normal browsing, the company has been urgent to check and modify the obvious areas of the shop page, and hereby solemnly states that all absolute words of the shop are invalid and not used as compensation reasons; The company will never accept and compromise the online fraud in the name of fighting against counterfeits in any form. Please make way for real consumers. The protection of rights is two-way. I hope all consumers will understand, and those who are trying to seek illegitimate interests will appreciate it!